Product Description
*** Priced to include UV lighting option as well as base stand - inquire for pricing if options are not required. This model has a sash opening of 10 in., but you can request the 8 in. version at the same cost ***
This 4' Purifier Logic+ Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. It is designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research. During operation, room air is drawn into the inlet grill. The air in the plenum beneath the work surface is a mixture of unfiltered room airand air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter.
FEATURES:
~ Electronically Commutated Motor (ECM)
~ Constant Airflow Profile (CAP) Technology airflow monitoring system that communicates with the ECM to deliver the precise volume of air as required and automatically adjust as filters load without relying on airflow sensors
~ Air-Wave Entry System*
~ Contain-Air Negative Pressure Channel
~ Smart-Start System that allows the user to program start up and shut down operations
~ Night-Smart System that idles the blower when the sash is fully closed
~ Built-in interval or elapsed timer for experiment monitoring, fluorescent light or UV light control (on models with UV light)
~ Digital clock
~ Removable towel catch located under work surface
~ Bright, 90-100 footcandle, glare-free fluorescent lighting located outside the contaminated work area
~ LCD information center with 'Filter Life Remaining' bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 0%
~ Electronic security lock (optional activation) that requires code to operate the cabinet
~ Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption (115 volt models)
~ Intrinsically safe negative pressure design
~ Fully-closing, clear 1/4 in. tempered safety glass sash
~ Stainless steel inlet grille with Reserve-AirÖ Secondary Airflow Slots
~ Supply and exhaust 99.99% efficient HEPA filters. Contact Labconco for optional 99.999% efficient ULPA filters.
~ Leak-tight stainless steel interior
~ Interior-mounted, line-of-sight, full color LCD information center with easy-to-understand MyLogic OS
~ 21.7 in. (54 cm) maximum sash opening height and 27.0 in. (69 cm) viewing height
~ Curved inlet grille for forearm support
~ Flush-mounted stainless steel electrical receptacle covers with dampened hinges
~ Removable, seamless type 304 stainless steel, dished work surface with lift out knobs
~ 10° Angled sash with counterbalanced, anti-racking mechanism for ease of lifting
~ ADA-compliant touchpad control on right-hand side post for manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection
~ Noise level less than 63 dBA
~ Heat load 990 BTU/hour (4' models)
~ Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec)
~ Nominal downflow velocity of 55 fpm (0.3 m/sec)
~ Approximately 70% air recirculation
~ Powder-coated steel exterior
~ NSF, ETL, CE conformity marking (230 volt models)
~ Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
Exhaust Volume: 253-279 CFM
Lighting: Fluorescent and Ultraviolet
Sash Opening: 10 in.
Service Fixtures: One
Includes: base stand
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Labconco 302411101 Logic+ Class II A2 Laminar Flow Biohazard or copy the following into your browser address window: labequip.com/stock/pictures/n1264.pdf
Made in USA.