Product Description
***The Lovibond TB350 WL Turbidity Meter is directly comparible to the HACH 2100Q Portable Turbidimeter***
REQUEST PRICING ON THE IR VERSION, WHICH HAS AN IR LED LIGHT SOURCE AND IS ISO 7027 COMPLIANT
The TB350 turbidimeter delivers the most reliable measurements for low range to high range samples, without sacrificing accuracy. It is ideal for field applications such as distribution monitoring, environmental samples or customers that test a wide range of samples.
Highlights
~ Reads up to 4000 NTU without the need for dilutions
~ Fast Settling Mode increases accuracy of readings with large or heavy particles
~ Easily save and recall measurement data sets
~ Touchscreen interface for ease of operation
The TB350 WL portable turbidimeter is designed for use in the field. Distribution system monitoring, environmental testing or even labs that test a wide range of samples are ideal applications. The instrument includes features and tools to prevent common turbidity measurement mistakes and encourage best practices to ensure the best results
Ideal for field and environmental testing, the TB350 turbidimeter delivers the most reliable measurements for low range to high range samples without sacrificing accuracy. Featuring the patent-pending Multipath 90° BLAC® sensor technology, the optical system is engineered with dual detectors to deliver a ratio reading which mitigates common measurement stability issues.
The intuitive, touchscreen interface makes it easy to perform procedures and interpret results. With function applications, you can navigate between settings and performing that function efficiently. This user interface eliminates common frustrations and prevents errors. The data logging capabilities allow you to record the testing location, operator's identification, time and date along with the measurement. Stored data can be transferred to a computer via USB.
Supplied ready-to-use with sample cells, silicone oil and calibration standards in carrying case.
SPECIFICATIONS:
Light Source: White LED
Regulatory Compliance: EPA pending
Measuring Principle: Nephelometric (Multipath 90° BLAC)
Measuring Range: 0.01 - 4000 NTU (FNU)
Resolution: Auto ranging: 0.01-9.99: 0.01 NTU ; 10.0-99.9: 0.1 NTU ; 100-4000: 1 NTU
Accuracy: ± 1.8 % of reading + straylight
Repeatability: less than 1 % or ± 0.01 NTU
Display Units: NTU, FNU, Degrees, mg/l Kaolin, mg/l PSL
Response Time: 7 seconds
Reading Modes: Single, Signal Averaging, Fast-Settling
Calibration Options: Full-range calibration from 0 - 4000 NTU
Detector: Silicon Photodiode
Sample Required: 10 mL (0.4 oz)
Display: Full-Colour Touchscreen
Interfaces:
~ USB-A
~ USB-C
Data Logger: 250 measurements, all calibrations, verifications and factory-restore actions
Data Transfer Format: .csv
Power Save Mode: Yes
Auto - OFF: Selectable
Power Requirements: Alkaline batteries, 4 x AA (included) ; Rechargeable battery pack, 3 x AA NiMH (optional) ; Power supply set, AC 100 - 240 V, 50/60 Hz (optional)
Applications: Drinking Water Treatment Pool Water Control Pool Water Treatment Waste Water Treatment
The following link provides additional information from the manufacturer's brochure. Click to open the PDF in a new window or right-click to download it:
Lovibond-Tintometer TB350 WL Portable Turbidity Meter or copy the following into your browser address window: labequip.com/stock/pictures/n2201.pdf
Made in USA.
ACCESSORIES:
COMES COMPLETE WITH:
- Instrument
- Set of ready-to-use turbidity standards in sealed vials for calibration
- 5 NTU turbidity standard in sealed vial for
verification
- Silicone oil
- Cleaning cloth
- Brush for sample vials
- Sample cells with black lids (2)
- Screwdriver
- AA Batteries (4)
- Multi-lingual Quick Start Guide
- Carrying case with removable insert
OPTIONAL ACCESSORIES AVAILABLE AT ADDITIONAL COST:
Vial Stand acrylic; for 6 vials
Rechargeable Battery Pack
Sample Cells, pack of 12 with black lids
Calibration Kit: Includes: 5/20/800/2000/4000 NTU standards